banner
DC Current Voltage Transducer

DC Current Voltage Transducer

APPLICATION Oil system; Power plant; Industrial filed; Coal auto system; Rail electrical system; Electricity power compa
SHARE

Description

Basic Info.
Model NO. FUD-DI-DU
Certification ISO
Customized Customized
Dimension 55mm×75mm×120mm
DC Output Range 0-5V, 4-20mA
Accuracy 0.2%, 0.5%
Temperature -10 to +50 Degree
Input Range DC 0-10A, DC 0-500V(Optional)
Transport Package Standard Export Carton
Specification CE
Trademark GFUVE
Origin Beijing China
Production Capacity 500/Month
Product Description

DC Current Voltage Transducer

DC Current Voltage Transducer

DC Current Voltage Transducer

DC Current Voltage Transducer

APPLICATION

Oil system;

Power plant;

Industrial filed;

Coal auto system;

Rail electrical system;

Electricity power company;

Metallurgy electrical system;

FEATURES

DC voltage transducer;

DC current transducer;

Accuracy class can reach 0.2%;

DC input range can be customized;

DC output range can be customized;

Technical Index

Technical Index
StandardQB/441600 17 079-2001
Accuracy0.2%, 0.5%
Consumption≤3VA
Accuracy driftAnnual variation <0.2%
Insulation voltageAC 2kV/min.1mA (Between input- output/power)
Insulation resistance≥20MΩ (DC500V)
Surge voltage5KV (peak value), 1.2/50μs
Response time≤350ms
Input rangeAC 0-10A ,AC 0-500V(Option)
Absorbed power≤0.1VA
OverloadCurrent: 2 times continuous, 20 times/1s;
Load resistanceCurrent output: RL ≤550Ω
Voltage output: RL ≥2kΩ
Working environmentTemperature: -10 to +50°C
RH: 20-90%, without condensation
Storage conditionsTemperature: -40 to +70°C
RH: 20-95%, without condensation
Installation35mm DIN sliding-way or M4 screws
Dimension55mm x 75mm x 120mm

Model Description

FUD-Type-Input-Power Supply-Output
TypeDI: DC current transducer
DV: DC voltage transducer
DC inputA1: 0-75mA, A2: 0-100mA, A3: 0-±75mV, A4: 0-±100mV, A5: 0-20mA, A6: 4-20mA, A7: 0-5A, A8: 0-15A, V0: 0-5V, V1: 0-30V, V2: 0-60V, V3: 0-300V, V4: 0-400V, V5: 0-450V, Vn: User define.
Power supplyP1: AC 85-265V or DC 100-330V, P2: DC 20-60V.
DC outputO1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: 1-3-5V, O6: 4-12-20mA.
Example 1: FUD-DI-A2-P1-O4
FUD series DC current transducerInput: DC 0-100mA
Power supply: AC220V±15%
Output: DC4-20mA
Example 2: FUD-DU-V3-P1-O4
Details: FUD series DC voltage transducerInput: DC 0-300V
Power supply: AC220V±15%
Output: DC4-20mA
*Please check the type, input range, output range and power supply when your order the product.

Our Contact